Showing results: 436 - 450 of 523 items found.
-
5158 -
Abaco Systems Inc
The 5158 Electrical Conversion Module (ECM) provides eight (8) RS-232 outputs and eight (8) RS-232 inputs. Built around Maxim 1488 & 1489 chips for true RS232 levels and voltage tolerance, all outputs come up in the 1, mark or idle state. Electrically this is a negative output voltage, the start bit is always a 0 or a positive voltage level.
-
Renesas Electronics Corp.
Modern dual protocol transceivers simplify the design of industrial interfaces due to their high level of integration, combined support of RS-232 and RS-485 protocols, programmable data rates, and power-saving configuration features. To support system engineers in their industrial networking designs, Renesas provides a wide range of fixed and programmable, single and dual channel, multi-protocol transceivers.
-
Model TCIC -
Industrial Measurement Systems Ltd.
High Speed 8 Channel Thermocouple Interface CardPDF VersionModel TCIC Thermocouple Interface Card with USB or RS232 / 485Main FeaturesLow cost high speed thermocouple measurement 400 channels / second
-
Hamlet Video International Ltd
The MSC remote control panels operate over a standard 10BaseT Ethernet LAN. Most other switcher manufacturers either offer no remote control panels and rely solely on expensive third party control''s connected to the RS232 port, one remote panel that ties up the RS232 port or some form of proprietary multi-panel interconnect scheme. Typically these proprietary systems have no isolation between control panels. If one panel fails possibly all of the panels on the network can be locked out until the failed panel is found and removed or fixed.
-
ECD485 -
EDMI Ltd.
Deploy sub-metering sites and simple metering networks with ease using the EDMI MiniHub RS-232 to RS-485 converter.1/4 Load RS-485 modules allow for up to 128 devices over 1.2km of wired daisy-chain network, with each meter capable of becoming the Network Master and remotely connecting to a backhaul system via an integrated EDMI Modem Port redirect connector.
-
Brighton Electronics
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
MBDC-200 -
proconX Pty Ltd
MBDC-200 is an autonomous Modbus data concentratorand collector. The MBDC-200 features two serial ports which can be configured as either RS-232 or RS-485 layer or by combining the two ports as a single RS-422 link. The data concentrator has also an Ethernet port and can be mounted on a DIN rail.
-
MBRG-300 -
proconX Pty Ltd
MBRG-300 is an advanced Modbus gateway and router.The MBRG-300 features two serial ports which can be configured as either RS-232 or RS-485 layer or by combining the two ports as a single RS-422 link. The router has also an Ethernet port and can be mounted on a DIN rail.
-
MODG-100 -
proconX Pty Ltd
MODG-100 is a Modbus/TCP to Modbus RTU gateway. Itfeatures one serial port which can be configured as either RS-232, RS-485 or RS-422 and an Ethernet port. It can be mounted on a DIN rail.
-
SERIP-100 -
proconX Pty Ltd
SERIP-100 is proconX' low-cost Industrial device server offering one or two software selectable RS-232/422/485 serial ports and a 10 Mbit Ethernet port.
-
Ophir RF
Systems are complete. They plug into an outlet and are ready to go. Our standard systems are 3U, which is 5.25″ and 5U, 8.75″. Systems are available with or without IEEE-488, RS-232 and Ethernet connectivity. Amplifiers Systems are available in both Broadband and Band-Specific frequencies. We are well-known in the industry for successfully adapting our amplifiers or custom designing new solutions to suit each unique project. Please refer to our Adapted & Custom Design Solutions link to begin formulating your performance objectives and other criteria.
-
16502 -
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
61610 -
Chroma Systems Solutions, Inc.
Power Rating:61511/61611: 12KVA61512/61612: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation
-
11022/11025 -
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
Excalibur Systems, Inc.
Serial Module for Multi Protocol 4000 BoardsNOTE: The M4KSerial module is now a Legacy product. All new projects should use the M4KSerialPlus module (these modules are not compatible)